Elektron · Groovebox

Model:Samples MIDI CC chart

All 29 CC numbers of the Model:Samples: pitch, decay, start, length, filter and sends for each track, loop and reverse, the LFO, and the delay and reverb.

29 parameters · 4 sections · plain CC, no NRPN

Download PDFA4, ready to print. Keep it next to the Model:Samples.

Track15

Playback2

LFO8

FXFX ch4

How the Model:Samples takes CC

Channels

Track, Playback and LFO controls listen on each track's own channel, T1 IN to T6 IN, or on the AUTO channel for the active track. Delay and Reverb listen on the separate FX IN channel.

Switches

Loop is CC 17 and Reverse is CC 18. Both are switches, as are Mute on CC 94 and the LFO Reset on CC 108.

Source

Transcribed from the Model:Samples User Manual, then read against it a second time. The same chart is a printable PDF. Found a wrong number? Write to hello@synthycraft.com and it gets fixed.

Questions people ask

What CC is filter cutoff on the Model:Samples?

Cutoff is CC 74 and Resonance is CC 71, on the track's channel.

What CC sets sample start and length on the Model:Samples?

Start is CC 19 and Length is CC 20. Pitch is CC 16 and Decay is CC 80.

Which MIDI channel does the Model:Samples listen on?

Each of the six tracks has its own input channel, and the AUTO channel reaches the active track. Delay and reverb listen on FX IN.

Sequentia for iPhone and iPad

Turn these knobs from your phone

Sequentia has this chart built in. Pick the Model:Samples and its real controls are on your iPhone or iPad as knobs and switches, with a looper for knob movement and tempo-locked LFOs on any CC.