Elektron · Drum machine
Syntakt MIDI CC chart
Every plain CC of the Syntakt: the eight machine parameters, filter, amp and two LFOs of a track, then the delay, reverb, the FX track and the external input on the FX Control channel.
86 parameters · 11 sections · plain CC, no NRPN
Track3
Trig7
Source8
Filter11
Amp9
LFO 18
LFO 28
DelayFX ch8
ReverbFX ch7
FX TrkFX ch12
Ext InFX ch5
No parameter matches. A number finds that CC exactly, a word finds a parameter or a section.
How the Syntakt takes CC
Channels
Most controls listen on the track's own MIDI channel, or on the auto channel for the active track. Everything marked FX ch (Delay, Reverb, FX Trk and Ext In) listens on the separate FX Control channel.
Machine parameters
The Source group is Syn A to Syn H on CC 17 to 24. What each one does follows the machine loaded on that track, so the chart keeps the letters.
Source
Transcribed from the Syntakt User Manual, then read against it a second time. The same chart is a printable PDF. Found a wrong number? Write to hello@synthycraft.com and it gets fixed.
Questions people ask
What CC is filter cutoff on the Syntakt?
Cutoff is CC 74 and Reso is CC 75 on the track's channel. The FX track has a filter of its own: Cutoff CC 70 and Reso CC 71 on the FX Control channel.
What CC are the machine parameters on the Syntakt?
Syn A to Syn H are CC 17 to 24 on the track's channel. Their meaning changes with the machine on the track.
Which MIDI channel does the Syntakt FX track listen on?
The FX track, the delay, the reverb and the external input listen on the FX Control channel. The twelve tracks each listen on their own channel.
Sequentia for iPhone and iPad
Turn these knobs from your phone
Sequentia has this chart built in. Pick the Syntakt and its real controls are on your iPhone or iPad as knobs and switches, with a looper for knob movement and tempo-locked LFOs on any CC.